Model and Suffix Codes

DX1000

Model
code
Suffix code
Optional code
Description
DX1002     2 ch, 125 ms (Fast sampling mode: 25 ms)
DX1004     4 ch, 125 ms (Fast sampling mode: 25 ms)
DX1006     6 ch, 1 s (Fast sampling mode: 125 ms)
DX1012     12 ch, 1 s (Fast sampling mode: 125 ms)
Internal memory -3   400 MB
External media           -4   CF card (with media)
Display language           -2   English, degF, DST(summer/winter time)
Options /A1 Alarm output 2 points *1
/A2 Alarm output 4 points *1
/A3 Alarm output 6 points *1 *2
/C2 RS-232 interface *3
/C3 RS-422/485 interface *3
/F1 FAIL/Status output *2
/H2 Clamped input terminal (detachable)
/H5 Desktop type (for /P1 model, without power code, screw type power terminal) *4
/H5[ ] Desktop type *5
/M1 Mathematical functions
/N1 Cu10,Cu25 RTD input/3 leg isolated RTD
/N2 3 leg isolated RTD *6
/N3 Extended input type (PR40-20, Pt50, etc.)
/P1 24 VDC/AC power supply *4
/R1 Remote control
/TPS2 24 VDC transmitter power supply (2 loops) *7
/TPS4 24 VDC transmitter power supply (4 loops) *8
/KB1 Easy text entry (with input terminal) *9 *10
/KB2 Easy text entry (without input terminal) *9
/USB1 USB interface
/PM1 Pulse input (including remote control and mathematical functions) *11
/CC1 Calibration correction function
/BT2 Multi-batch functions *12
/CP1 PROFIBUS-DP functions *3
/AS1 Advanced security functions (Part 11 compliant)

*1 /A1, /A2 and /A3 cannot be specified together.
*2 /A3 and /F1 cannot be specified together.
*3 /C2, /C3 and /CP1 cannot be specified together.
*4 In case that 24 VDC/AC power supply (/P1) and desktop type are specified together,
    /H5 must be specified. /P1 and /H5[ ] cannot be specified together.
*5 /H5[ ]
           D: Power cord UL, CSA st'd
           F: Power cord VDE st'd
           R: Power cord SAA st'd
           J: Power cord BS st'd
           H: Power cord GB st'd
*6 /N2 can be specified for only DX1006 and DX1012.
*7 In case that /TPS2 is specified, /TPS4, /A2, /A3 or /F1 cannot be specified together.
*8 In case that /TPS4 is specified, /TPS2, /A1, /A2, /A3 or /F1 cannot be specified together.
*9 /KB1 and /KB2 cannot be specified together.
*10 In case that /KB1 is specified, remote input terminal (438227) is included.
*11 In case that /PM1 is specified, /A3, /M1, /R1, /TPS2 or /TPS4 cannot be specified.
       And combination of /A2/F1 cannot be specified together.
*12 /BT2 can be specified for only DX1006, DX1012.


DX2000

Model
code
Suffix code
Optional code
Description
DX2004     4 ch, 125 ms(Fast sampling mode: 25 ms)
DX2008     8 ch, 125 ms(Fast sampling mode: 25 ms)
DX2010     10 ch, 1 s(Fast sampling mode: 125 ms)
DX2020     20 ch, 1 s(Fast sampling mode: 125 ms)
DX2030     30 ch, 1 s(Fast sampling mode: 125 ms)
DX2040     40 ch, 1 s(Fast sampling mode: 125 ms)
DX2048     48 ch, 1 s(Fast sampling mode: 125 ms)
Internal memory  -3   400 MB
External media            -4   CF card (with media)
Display language            -2   English, degF, DST(summer/winter time)
Options /A1 Alarm output 2 points *1
/A2 Alarm output 4 points *1 *12
/A3 Alarm output 6 points *1
/A4 Alarm output 12 points *1 *9 *12
/A5 Alarm output 24 points *1 *2 *8 *12
/C2 RS-232 interface *3
/C3 RS-422/485 interface *3
/D5 VGA output
/F1 FAIL/Status output *2 *4 *9
/F2 FAIL + Alarm output 22 points *1 *4 *8 *12
/H2 Clamped input terminal (detachable)
/H5 Desktop type (for /P1 model, without power code, screw type power terminal) *5
/H5[ ] Desktop type *6
/M1 Mathematical functions *12
/N1 Cu10, Cu25 RTD input/3 leg isolated RTD
/N2 3 leg isolated RTD *7
/N3 Extended input type (PR40-20, Pt50, etc.)
/P1 24 VDC/AC power supply *5
/R1 Remote control *12
/TPS4 24 VDC transmitter power supply (4 loops) *8
/TPS8 24 VDC transmitter power supply (8 loops) *8 *9 *12
/KB1 Easy text entry (with input terminal) *10 *11
/KB2 Easy text entry (without input terminal) *10
/USB1 USB interface
/PM1 Pulse input (including remote control and mathematical functions) *12
/CC1 Calibration correction function
/MC1 External input function *13
/BT2 Multi-batch functions *14
/CP1 PROFIBUS-DP functions *3
/AS1 Advanced security functions (Part 11 compliant)

*1 /A1, /A2, /A3, /A4, /A5, and /F2 cannot be specified together.
*2 /A5 and /F1 cannot be specified together.
*3 /C2, /C3, and /CP1 cannot be specified together.
*4 /F1 and /F2 cannot be specified together.
*5 In case that 24 VDC/AC power supply (/P1) and desktop type are specified together,
     /H5 must be specified. /P1 and /H5[ ] cannot be specified together.
*6 /H5[ ]
           D: Power cord UL, CSA st'd
           F: Power cord VDE st'd
           R: Power cord SAA st'd
           J: Power cord BS st'd
           H: Power cord GB st'd
*7 /N2 can be specified only for DX2010, DX2020, DX2030, DX2040 and DX2048.
*8 /TPS4, /TPS8, /A5 and /F2 cannot be specified together.
*9 If /TPS8 is specified, /A4 and /F1 cannot be specified together.
*10 /KB1 and /KB2 cannot be specified together.
*11 If /KB1 is specified, a remote control terminal (438227) is included.
*12 If /PM1 is specified, /A5, /F2, /M1, and /R1 cannot be specified together.
       The combination of /A2/F1 and the combination of /A4/TPS8 cannot be specified together.
*13 /MC1 can be specified only for the DX2010, DX2020, DX2030, DX2040, and DX2048.
*14 /BT2 can only be specified for the DX2010, DX2020, DX2030, DX2040, and DX2048.


Application Software

Model code
Description
O S
DXA120 DAQSTANDARD Windows 2000/XP/Vista
DXA170 DAQStudio (sold seperately) Windows XP/Vista
DXA250 DAQmanager (sold seperately) Windows XP/Vista



Accessories

Product
Model code (part number)
Specification
Shunt resister
(for screw input terminal)
415920 250Ω±0.1%
415921 100Ω±0.1%
415922 10Ω±0.1%
Shunt resister
(for clamped input terminal)
438920 250Ω±0.1%
438921 100Ω±0.1%
438922 10Ω±0.1%
CF card adapter 772090
CF card 772093 512MB
772094 1GB
Mounting bracket B9900BX
Door lock key B8706FX
Remote control terminal 438227 For /KB1, /KB2 option
Validation document 438230 For /AS1 option